device15-aae41fc9083bfb1db6b41ca071440eb7

AKO-15440, AKO-15490

Range from -99,9 ºC to +1370 ºC, 48 x 48 format

Input for Pt100 probe, J and K thermocouple.

Application: Ovens, electrical panels, industrial installations, etc.

ON/OFF Control. Programmable for cold and heat. With the 2 outputs, the controller can be used to work as a stage plus alarm.

device15-535254ce5ebd773f310e8f62b9268842

AKO-15400, AKO-15450

Range from -99,9 ºC up to +1370 ºC, 48 x 48 format

Input for Pt100 probe, Thermocouple J and K, 4-20mA.

Application: Ovens, electrical panels, industrial installations, etc.

Programmable for cold and heat. Controller PID or ON/OFF programme-selectable. Self-tuning function. Probe input configurable as Pt100, thermocouple J and K, 4-20mA. With the 2 outputs, the controller can be used to work as a stage plus alarm. Digital input configurable for SetPoint change or start-stop of the unit.

device15-143bc00710e93eb5f2a8543bd9a5a329

AKO-15430, AKO-15437, AKO-15480, AKO-15487

Range -99,9 ºC to +1370 ºC, output 4-20 mA/0-10 V, format 48 x 48

With 4-20mA/0-10V output.

Application: Ovens, electrical panels, industrial installations, etc.

Programmable for cold and heat. Controller PID or ON/OFF programme-selectable. Self-tuning function. Probe input configurable as Pt100, thermocouple J and K, 4-20 mA. With the 2 outputs, the controller can be used to work as a stage plus alarm. With the 4-20 mA/0-10V output option, we have an analogue output to govern a valve or to resend the signal to a variator or PLC. With the RS-485 communication option, the unit can be connected to a network working with ModBus protocol.

device15-8b4139128ac41c5d433b217fa3675cd6

AKO-15410, AKO-15413, AKO-15415, AKO-15460, AKO-15463, AKO-15465

Range from -99,9 ºC to +1370 ºC, 3 relays, format 48 x 48

With additional relay output.

Application: Ovens, electrical panels, industrial installations, etc.

Programmable for cold and heat. Controller PID or ON/OFF programme-selectable. Self-tuning function. Probe input configurable as Pt100, thermocouple J and K, 4-20 mA. Digital input configurable for SetPoint change or start-stop of the unit. With the 3 outputs, the controller can operate as a two stage, a neutral zone, with alarm signalling. With the 4-20 mA/0-10V output option, we have an analogue output to govern a valve or to resend the signal to a variator or PLC. With the option of an input for current transformer (C.T.) the breakage of the heating resistance can be detected.

device15-493431fcddd78bd5d64eebb95249c1c4

AKO-15401, AKO-15402, AKO-15403, AKO-15451, AKO-15452, AKO-15453

With RS485 communication, format 48 x 48

Communication and input for current transformer.

Application: Ovens, electrical panels, industrial installations, etc.

Programmable for cold and heat. Controller PID or ON/OFF programme-selectable. Self-tuning function. Probe input configurable as Pt100, thermocouple J and K, 4-20 mA. With the 2 outputs, the controller can be used to work as a stage plus alarm. With the option of an input for current transformer (C.T.) the breakage of the heating resistance can be detected. With the RS-485 communication option, the unit can be connected to a network working with ModBus protocol.