CONSTANT WATTAGE PARALLEL CABLES. CABLE WITH PVC INSULATION
AKOCABLE
CHARACTERISTICS
CONDUCTORS 2 x 1.5 mm2.
Exposure temperature up to 70 ºC with PVC insulation.
AKO-5231 heating cable designed to prevent cracks in the ground of cold room stores installed under thermal insulation.
AKO-1212 heating cable for underground heating installed above the thermal insulation.
TECHNICAL SPECIFICATIONS
- Copper conductor 2 x 1.5 mm2.
- Ni – Cr heating conductor element.
- Nominal outer dimensions 9 x 6 mm.
- Minimum radius of curvature of 20 mm at -15 ºC.
- Maximum exposure temperature (disconnected) 70 ºC.
- Heating zone length 1,000 mm.
Application: Refrigeration and construction
REFERENCES
Description | Model |
Heating cable 10 W / m at 230 V (PVC insulation) | AKO-5231 |
Heating cable 20 W / m at 230 V (PVC insulation) | AKO-1212 |
CONSTANT WATTAGE PARALLEL CABLES. FLEXIBLE CABLE WITH SILICONE INSULATION
AKOCABLE
TECHNICAL SPECIFICATIONS
CONDUCTORS 2 x 0.75 mm2.
Exposure temperature up to 180 ºC with sillicone insulation.
Heating cables that are commonly used in refrigeration installations to avoid ice in drain pipes and door frames, as well as to avoid condensation on surfaces. They can be cut to length.
TECHNICAL SPECIFICATIONS
- Copper conductor 2 x 0.75 mm2.
- Ni – Cr heating conductor element.
- Nominal outer dimensions 8 x 6 mm.
- Minimum radius of curvature of 10 mm at -40 ºC.
- Maximum exposure temperature (disconnected) 180 ºC.
- Heating zone length 595 mm.
Applications: Industrial and commercial refrigeration
Description | Model |
Heating cable 30 W/m at 230 V, silicone insulation | AKO-5234 |
Heating cable 30 W/m at 120 V, silicone insulation | AKO-52342 |
Heating cable 40 W/m at 230 V, silicone insulation | AKO-52344 |
Heating cable 65 W/m at 230 V, silicone insulation | AKO-52346 |
CONSTANT WATTAGE PARALLEL CABLES. FLEXIBLE CABLE WITH SILICONE INSULATION
AKOCABLE
CHARACTERISTICS
CONDUCTORS 2 x 1.5 mm2.
Exposure temperature up to 180 ºC with sillicone insulation.
Heating cables that are commonly used in refrigeration installations to avoid ice in drain pipes as well as to avoid condensation on surfaces. They can be cut to length
TECHNICAL SPECIFICATIONS
- Copper conductor 2 x 1.5 mm2.
- Ni – Cr heating conductor element.
- Nominal outer dimensions 9 x 6 mm.
- Minimum radius of curvature of 20 mm at -40 ºC.
- Maximum exposure temperature (disconnected) 180 ºC.
- Heating zone length 500 mm.
Applications: Refrigeration and construction
Description | Model |
Heating cable 50 W/m at 230 V, silicone insulation | AKO-712545 |
CONSTANT WATTAGE PARALLEL CABLES. SILICONE INSULATION + METAL BRAID
AKOCABLE
CHARACTERISTICS
CONDUCTORS 2 x 0.75 mm2.
Exposure temperature up to 70 ºC with metal braid protection. Heating cables that are commonly used in refrigeration installations to avoid ice in drain pipes and door frames, as well as to avoid condensation on surfaces. They have a metallic braid for grounding. They can be cut to size.
TECHNICAL SPECIFICATIONS
- Copper conductor 2 x 0.75 mm2.
- Ni – Cr heating conductor element.
- External dimensions less than or equal to 9 x 7 mm.
- Minimum radius of curvature of 10 mm at -40 ºC.
- Maximum exposure temperature (disconnected) 70 ºC / 180 ºC.
- Heating zone length 595 mm.
Applications: Industrial and commercial refrigeration
REFERENCES
Description | Model |
Heating cable 30 W/m at 230 V, insulation + metal braid | AKO-52341 |